Opentrons Integration
"Lab automation platform for Flex/OT-2 robots. Write Protocol API v2 protocols, liquid handling, hardware modules (heater-shaker, thermocycler), labware management, for automated pipetting workflows."
$ npx claude-code-templates@latest --skill="scientific/opentrons-integration" --yesRequires Claude Code. The command adds this skill to your project's .claudedirectory — nothing runs on ToolZip's servers.
What's inside this skill
Component source (preview)
Opentrons Integration
Overview
Opentrons is a Python-based lab automation platform for Flex and OT-2 robots. Write Protocol API v2 protocols for liquid handling, control hardware modules (heater-shaker, thermocycler), manage labware, for automated pipetting workflows.
When to Use This Skill
This skill should be used when:
- Writing Opentrons Protocol API v2 protocols in Python
- Automating liquid handling workflows on Flex or OT-2 robots
- Controlling hardware modules (temperature, magnetic, heater-shaker, thermocycler)
- Setting up labware configurations and deck layouts
- Implementing complex pipetting operations (serial dilutions, plate replication, PCR setup)
- Managing tip usage and optimizing protocol efficiency
- Working with multi-channel pipettes for 96-well plate operations
- Simulating and testing protocols before robot execution
Core Capabilities
1. Protocol Structure and Metadata
Every Opentrons protocol follows a standard structure:
from opentrons import protocol_api
# Metadata
metadata = {
'protocolName': 'My Protocol',
'author': 'Name <email@example.com>',
'description': 'Protocol description',
'apiLevel': '2.19' # Use latest available API version
}
# Requirements (optional)
requirements = {
'robotType': 'Flex', # or 'OT-2'
'apiLevel': '2.19'
}
# Run function
def run(protocol: protocol_api.ProtocolContext):
# Protocol commands go here
pass
Key elements:
- Import
protocol_apifromopentrons - Define
metadatadict with protocolName, author, description, apiLevel - Optional
requirementsdict for robot type and API version - Implement
run()function receivingProtocolContextas parameter - All protocol logic goes inside the
run()function
2. Loading Hardware
Loading Instruments (Pipettes):def run(protocol: protocol_api.ProtocolContext):
# Load pipette on specific mount
left_pipette = protocol.load_instrument(
'p1000_single_flex', # Instrument name
'left', # Mount: 'left' or 'right'
tip_racks=[tip_rack] # List of tip rack labware objects
)
Common pipette names:
- Flex:
p50_single_flex,p1000_single_flex,p50_multi_flex,p1000_multi_flex - OT-2:
p20_single_gen2,p300_single_gen2,p1000_single_gen2,p20_multi_gen2,p300_multi_gen2
# Load labware directly on deck
plate = protocol.load_labware(
'corning_96_wellplate_360ul_flat', # Labware API name
'D1', # Deck slot (Flex: A1-D3, OT-2: 1-11)
label='Sample Plate' # Optional display label
)
# Load tip rack
tip_rack = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1')
# Load labware on adapter
adapter = protocol.load_adapter('opentrons_flex_96_tiprack_adapter', 'B1')
tips = adapter.load_labware('opentrons_flex_96_tiprack_200ul')
Loading Modules:
# Temperature module
temp_module = protocol.load_module('temperature module gen2', 'D3')
temp_plate = temp_module.load_labware('corning_96_wellplate_360ul_flat')
# Magnetic module
mag_module = protocol.load_module('magnetic module gen2', 'C2')
mag_plate = mag_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
# Heater-Shaker module
hs_module = protocol.load_module('heaterShakerModuleV1', 'D1')
hs_plate = hs_module.load_labware('corning_96_wellplate_360ul_flat')
# Thermocycler module (takes up specific slots automatically)
tc_module = protocol.load_module('thermocyclerModuleV2')
tc_plate = tc_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
3. Liquid Handling Operations
Basic Operations:# Pick up tip
pipette.pick_up_tip()
# Aspirate (draw liquid in)
pipette.aspirate(
volume=100, # Volume in µL
location=source['A1'] # Well or location object
)
# Dispense (expel liquid)
pipette.dispense(
volume=100,
location=dest['B1']
)
# Drop tip
pipette.drop_tip()
# Return tip to rack
pipette.return_tip()
Complex Operations:
# Transfer (combines pick_up, aspirate, dispense, drop_tip)
pipette.transfer(
volume=100,
source=source_plate['A1'],
dest=dest_plate['B1'],
new_tip='always' # 'always', 'once', or 'never'
)
# Distribute (one source to multiple destinations)
pipette.distribute(
volume=50,
source=reservoir['A1'],
dest=[plate['A1'], plate['A2'], plate['A3']],
new_tip='once'
)
# Consolidate (multiple sources to one destination)
pipette.consolidate(
volume=50,
source=[plate['A1'], plate['A2'], plate['A3']],
dest=reservoir['A1'],
new_tip='once'
)
Advanced Techniques:
# Mix (aspirate and dispense in same location)
pipette.mix(
repetitions=3,
volume=50,
location=plate['A1']
)
# Air gap (prevent dripping)
pipette.aspirate(100, source['A1'])
pipette.air_gap(20) # 20µL air gap
pipette.dispense(120, dest['A1'])
# Blow out (expel remaining liquid)
pipette.blow_out(location=dest['A1'].top())
# Touch tip (remove droplets on tip exterior)
pipette.touch_tip(location=plate['A1'])
Flow Rate Control:
# Set flow rates (µL/s)
pipette.flow_rate.aspirate = 150
pipette.flow_rate.dispense = 300
pipette.flow_rate.blow_out = 400
4. Accessing Wells and Locations
Well Access Methods:# By name
well_a1 = plate['A1']
# By index
first_well = plate.wells()[0]
# All wells
all_wells = plate.wells() # Returns list
# By rows
rows = plate.rows() # Returns list of lists
row_a = plate.rows()[0] # All wells in row A
# By columns
columns = plate.columns() # Returns list of lists
column_1 = plate.columns()[0] # All wells in column 1
# Wells by name (dictionary)
wells_dict = plate.wells_by_name() # {'A1': Well, 'A2': Well, ...}
Location Methods:
# Top of well (default: 1mm below top)
pipette.aspirate(100, well.top())
pipette.aspirate(100, well.top(z=5)) # 5mm above top
# Bottom of well (default: 1mm above bottom)
pipette.aspirate(100, well.bottom())
pipette.aspirate(100, well.bottom(z=2)) # 2mm above bottom
# Center of well
pipette.aspirate(100, well.center())
5. Hardware Module Control
Temperature Module:# Set temperature
temp_module.set_temperature(celsius=4)
# Wait for temperature
temp_module.await_temperature(celsius=4)
# Deactivate
temp_module.deactivate()
# Check status
current_temp = temp_module.temperature # Current temperature
target_temp = temp_module.target # Target temperature
Magnetic Module:
# Engage (raise magnets)
mag_module.engage(height_from_base=10) # mm from labware base
# Disengage (lower magnets)
mag_module.disengage()
# Check status
is_engaged = mag_module.status # 'engaged' or 'disengaged'
Heater-Shaker Module:
# Set temperature
hs_module.set_target_temperature(celsius=37)
# Wait for temperature
hs_module.wait_for_temperature()
# Set shake speed
hs_module.set_and_wait_for_shake_speed(rpm=500)
# Close labware latch
hs_module.close_labware_latch()
# Open labware latch
hs_module.open_labware_latch()
# Deactivate heater
hs_module.deactivate_heater()
# Deactivate shaker
hs_module.deactivate_shaker()
Thermocycler Module:
# Open lid
tc_module.open_lid()
# Close lid
tc_module.close_lid()
# Set lid temperature
tc_module.set_lid_temperature(celsius=105)
# Set block temperature
tc_module.set_block_temperature(
temperature=95,
hold_time_seconds=30,
hold_time_minutes=0.5,
block_max_volume=50 # µL per well
)
# Execute profile (PCR cycling)
profile = [
{'temperature': 95, 'hold_time_seconds': 30},
{'temperature': 57, 'hold_time_seconds': 30},
{'temperature': 72, 'hold_time_seconds': 60}
]
tc_module.execute_profile(
steps=profile,
repetitions=30,
block_max_volume=50
)
# Deactivate
tc_module.deactivate_lid()
tc_module.deactivate_block()
Absorbance Plate Reader:
# Initialize and read
result = plate_reader.read(wavelengths=[450, 650])
# Access readings
absorbance_data = result # Dict with wavelength keys
6. Liquid Tracking and Labeling
Define Liquids:# Define liquid types
water = protocol.define_liquid(
name='Water',
description='Ultrapure water',
display_color='#0000FF' # Hex color code
)
sample = protocol.define_liquid(
name='Sample',
description='Cell lysate sample',
display_color='#FF0000'
)
Load Liquids into Wells:
# Load liquid into specific wells
reservoir['A1'].load_liquid(liquid=water, volume=50000) # µL
plate['A1'].load_liquid(liquid=sample, volume=100)
# Mark wells as empty
plate['B1'].load_empty()
7. Protocol Control and Utilities
Execution Control:# Pause protocol
protocol.pause(msg='Replace tip box and resume')
# Delay
protocol.delay(seconds=60)
protocol.delay(minutes=5)
# Comment (appears in logs)
protocol.comment('Starting serial dilution')
# Home robot
protocol.home()
Conditional Logic:
# Check if simulating
if protocol.is_simulating():
protocol.comment('Running in simulation mode')
else:
protocol.comment('Running on actual robot')
Rail Lights (Flex only):
# Turn lights on
protocol.set_rail_lights(on=True)
# Turn lights off
protocol.set_rail_lights(on=False)
8. Multi-Channel and 8-Channel Pipetting
When using multi-channel pipettes:
# Load 8-channel pipette
multi_pipette = protocol.load_instrument(
'p300_multi_gen2',
'left',
tip_racks=[tips]
)
# Access entire column with single well reference
multi_pipette.transfer(
volume=100,
source=source_plate['A1'], # Accesses entire column 1
dest=dest_plate['A1'] # Dispenses to entire column 1
)
# Use rows() for row-wise operations
for row in plate.rows():
multi_pipette.transfer(100, reservoir['A1'], row[0])
9. Common Protocol Patterns
Serial Dilution:def run(protocol: protocol_api.ProtocolContext):
# Load labware
tips = protocol.load_labware('opentrons_flex_96_tiprack_200ul', 'D1')
reservoir = protocol.load_labware('nest_12_reservoir_15ml', 'D2')
plate = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D3')
# Load pipette
p300 = protocol.load_instrument('p300_single_flex', 'left', tip_racks=[tips])
# Add diluent to all wells except first
p300.transfer(100, reservoir['A1'], plate.rows()[0][1:])
# Serial dilution across row
p300.transfer(
100,
plate.rows()[0][:11], # Source: wells 0-10
plate.rows()[0][1:], # Dest: wells 1-11
mix_after=(3, 50), # Mix 3x with 50µL after dispense
new_tip='always'
)
Plate Replication:
def run(protocol: protocol_api.ProtocolContext):
# Load labware
tips = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1')
source = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D1')
dest = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D2')
# Load pipette
p1000 = protocol.load_instrument('p1000_single_flex', 'left', tip_racks=[tips])
# Transfer from all wells in source to dest
p1000.transfer(
100,
source.wells(),
dest.wells(),
new_tip='always'
)
PCR Setup:
```python
def run(protocol: protocol_api.ProtocolContext):
# Load thermocycler
tc_mod = protocol.load_module('thermocyclerModuleV2')
tc_plate = tc_mod.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
# Load tips and reagents
tips = protocol.load_labware('opentrons_flex_96_tiprack_200ul', 'C1')
reagents = protocol.load_labware('opentrons_24_tuberack_nest_1.5ml_snapcap', 'D1')
# Load pipette
p300 = protocol.load_instrument('p300_single_flex', 'left', tip_racks=[tips])
# Open thermocycler lid
tc_mod.open_lid()
# Distribute master mix
p300.distribute
Preview truncated. View the full source on GitHub →
Related Claude Code Skills
Generate Image
Generate or edit images using AI models (FLUX, Gemini). Use for general-purpose image generation including photos, illustrations, artwork, visual assets, concept art, and any image that isn't a technical diagram or schematic. For flowcharts, circuits, pathways, and technical diagrams, use the scientific-schematics skill instead.
Markitdown
"Convert files and office documents to Markdown. Supports PDF, DOCX, PPTX, XLSX, images (with OCR), audio (with transcription), HTML, CSV, JSON, XML, ZIP, YouTube URLs, EPubs and more."
Scientific Critical Thinking
"Evaluate research rigor. Assess methodology, experimental design, statistical validity, biases, confounding, evidence quality (GRADE, Cochrane ROB), for critical analysis of scientific claims."
Scientific Slides
"Build slide decks and presentations for research talks. Use this for making PowerPoint slides, conference presentations, seminar talks, research presentations, thesis defense slides, or any scientific talk. Provides slide structure, design templates, timing guidance, and visual validation. Works with PowerPoint and LaTeX Beamer."
Statistical Analysis
"Statistical analysis toolkit. Hypothesis tests (t-test, ANOVA, chi-square), regression, correlation, Bayesian stats, power analysis, assumption checks, APA reporting, for academic research."
Market Research Reports
"Generate comprehensive market research reports (50+ pages) in the style of top consulting firms (McKinsey, BCG, Gartner). Features professional LaTeX formatting, extensive visual generation with scientific-schematics and generate-image, deep integration with research-lookup for data gathering, and multi-framework strategic analysis including Porter's Five Forces, PESTLE, SWOT, TAM/SAM/SOM, and BCG Matrix."
Catalog data and component content are sourced from the open-source davila7/claude-code-templates project (MIT license). ToolZip curates the listing and writes original descriptions; every component links back to its original source. Claude Code is a product of Anthropic. ToolZip is an independent catalog and is not affiliated with or endorsed by Anthropic.